High Flow
Setup is simple and completed in minutes:
Step 1 – unload and stand in place, no guy wires
Step 2 – tie in waste gas line and pilot fuel source
Step 3 – hook up generator or power supply @ 480 volts / 3 phase / 60 amp service
Step 4 – open pilot fuel valve and push start button
AWI units are very safe and straightforward to operate. With only a 20 minute set up, the units are L skid mounted, simple to load, transport and erect. There are no anchors or guy wires needed allowing for zero ground disturbance.
Click to download the AWI High Flow Operation Procedure Manual
Visit the gallery for video and images of offloading and set up
Compared to flaring, the AWI technology offers:
- Combustion efficiency of 99.99% , with improved air quality and reduced greenhouse gas emissions
- Stable, consistent combustion in an enclosed and lined chamber, unaffected by winds
- No ground disturbance, free standing, no smoke, no visible flame, no odor
- No heat radiation at ground level for improved protection of arctic/tundra or sensitive environments, personnel and equipment
- 40 ft long x 11’ 6” wide x 16,500 Kg
- Rated Capacity at 6 MM SCFD Methane or 3 MM SCFD Typical Well Gas.
- Uses significantly less fuel than a flare to efficiently incinerate low heat content gases (H2S) with 99.99% combustion efficiency
- 40 ft exit elevation
- Dual continuous pilots
- Continuous temperature monitoring and recording
Competitive Rental Rates available upon request. Contact us 1-888-778-0960 or [email protected]
AWI Hi Flow Information Brochure